Characterisation and evaluation of a novel transmission detector for intra-fraction monitoring of radiotherapy.

Johnson, Daniel (2018) Characterisation and evaluation of a novel transmission detector for intra-fraction monitoring of radiotherapy. PhD thesis, University of Leeds.

[img]
Preview
Text
DJ_PhD_Thesis_Final.pdf - Final eThesis - complete (pdf)
Available under License Creative Commons Attribution-Noncommercial-Share Alike 2.0 UK: England & Wales.

Download (13Mb) | Preview

Abstract

The goal of this thesis was to characterise a novel transmission detector in the context of signal prediction. This was to eliminate the need to collect a baseline signal for the device before treatment. This not only saves time, but, by independently generating the baseline signal, the process is less prone to missing errors. A simple analytical algorithm was designed and was found to be capable of detecting gross errors, however, it was shown not to be accurate enough to detect MLC position errors that could have a clinical effect on the delivery. MU check software was commissioned, however the fluence distribution it produced lacked the complexity for accurate signal prediction. A Monte Carlo model of a linac was built and validated then used to demonstrate that the detector could be modelled as two slabs of Perspex; the signal being proportional to the dose measured in the air between them. Two Monte Carlo models were then made using different systems, these were both evaluated by comparing predicted signals to measured signals for VMAT plans. Both models performed well and were capable of detecting leaf errors ~1mm; the merits of both are discussed with regard to error detection and ease of use.

Item Type: Thesis (PhD)
Keywords: Radiotherapy, in-vivo dosimetry, transmission detector, Monte Carlo modelling
Academic Units: The University of Leeds > Faculty of Medicine and Health (Leeds) > Leeds Institute of Genetics, Health and Therapeutics (LIGHT) > Academic Unit of Medical Physics (Leeds)
Identification Number/EthosID: uk.bl.ethos.797960
Depositing User: Mr Daniel Johnson
Date Deposited: 08 Jan 2020 14:51
Last Modified: 11 Mar 2020 10:53
URI: http://etheses.whiterose.ac.uk/id/eprint/24417

You do not need to contact us to get a copy of this thesis. Please use the 'Download' link(s) above to get a copy.
You can contact us about this thesis. If you need to make a general enquiry, please see the Contact us page.

Actions (repository staff only: login required)