Maunder, Adam (2019) RF Coil Design, Imaging Methods and Measurement of Ventilation with 19F C3F8 MRI. PhD thesis, University of Sheffield.
Abstract
This thesis attempts to address the challenge of low signal in fluorinated gas ventilation imaging and optimize imaging methods considering the particular MR parameters of C3F8 by the following approaches:
(i) Exploration of coil designs capable of imaging both proton (1H – 63.8 MHz at 1.5T) and fluorine (19F – 60.1 MHz at 1.5T) nuclei involved:
1. The novel use of microelectromechanical systems to switch a single transceive vest coil between the two nuclei was compared to hard-wired or PIN diode switching.
2. The design of an 8 element transceive array with an additional 6 receive only coils for 19F imaging. MEMs was utilized for broadband transmit-receive switching.
3. The amalgamation of a ladder resonator coil with a 6-element transceive array to reduce SAR and improve transmit homogeneity when compared to standard vest coil designs.
(ii) Development of imaging methods involved:
1. The optimization and comparison of steady-state free precession and spoiled gradient 19F imaging with C3F8 at 1.5T and 3T. Simulation of the optimal SNR was verified through comprehensive phantom and in-vivo imaging experiments.
2. The investigation of compressed sensing via incoherent sparse k-space sampling to maximize the resolution in 19F ventilation imaging under the constraint of low SNR. Retrospective simulation with hyperpolarized gas images were corroborated by prospective 19F imaging of a 3D printed lung phantom and in-vivo measurements of the lungs.
(iii) In-vivo ventilation metrics obtained by 19F ventilation imaging were explored by:
1. The in-vivo mapping of T1 at 1.5T and 3T and mapping of FV and T2* at 3 T. The apparent diffusion coefficient (1.5T) and the evaluation of ventilated volume (1.5T and 3T) was also compared to imaging performed with 129Xe (1.5T).
2. The optimization of imaging for the evaluation of percent ventilated volume with 19F at 3T with a commercial birdcage coil.
Metadata
Supervisors: | Wild, Jim and Robb, Fraser and Rao, Madhwesha |
---|---|
Awarding institution: | University of Sheffield |
Academic Units: | The University of Sheffield > Faculty of Medicine, Dentistry and Health (Sheffield) > Medicine (Sheffield) |
Identification Number/EthosID: | uk.bl.ethos.786560 |
Depositing User: | Mr. Adam Maunder |
Date Deposited: | 30 Sep 2019 14:14 |
Last Modified: | 25 Mar 2021 16:51 |
Open Archives Initiative ID (OAI ID): | oai:etheses.whiterose.ac.uk:24805 |
Download
thesis_merge_AM_Final
Filename: thesis_merge_AM_Final.pdf
Licence:
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 2.5 License
Export
Statistics
You do not need to contact us to get a copy of this thesis. Please use the 'Download' link(s) above to get a copy.
You can contact us about this thesis. If you need to make a general enquiry, please see the Contact us page.